• Lift ERD Manufacturers

Emergency Rescue Device (ERD) for Lifts in Delhi, NCR, Gurugram, Haryana

Compatible with Regenerative lifts & Compatible with almost all Lift Brands

ERD – Emergency rescue device, ERD is essential for all high-rise buildings using high speed elevators so as to avoid any jerks during power cut / power fluctuations, to the passengers travelling inside the lift car and to ensure smooth operation of the lift.

In Haryana as per the state government rule, an ERD (an On Line UPS for individual Elevator) is essential so as to get BCC for any developer. ERD – Emergency rescue device, even though a DG set is installed at site and ARD for the elevator, ERD is essential for all high-rise towers using high speed (in some case regenerative drives OTIS, Thyssenkrupp at present) elevators so as to avoid any jerks during power cut / power fluctuations, to the passengers travelling inside the lift car and to ensure smooth operation of the lift.

Moreover, Haryana government officials are insisting that each individual lift must have a separate ERD meaning centralised combined UPS / ERD is NOT acceptable, with this the total number of UPS almost equals the number of lifts getting installed in Haryana.

ERD for High Rise Buildings | ERD for High-Speed Lifts

Renutron’s iERD: Intelligent Emergency Rescue Device for High-speed Lifts

High-speed Lifts

iERD Salient Features

  • Jerk free operation
  • Regen drive compatible
  • i-Smart lift car AV alerts
  • Built-in ARD
  • Echo model
  • Zero transfer
  • Lifepo4 Battery compatible
  • Remotely serviceable
  • Indigenously designs

Our Customers

Renutron iERD Solutions are an ideal substitute for DG sets

Renutron iERD ECO mode operation

For High Speed Regenerative drives used in high rise buildings

RENUTRON iERD with ECO mode is using an intelligent GRID synchronised technolgy specially designed for High Speed Regenerative drives used in high rise bulidings. In normal operation when the utility power is within safe limits, Lift operates on utility supply through a Static switch. The entire regenerative power generated by the Lift drive is returned back to the GRID.

MThus the same amount of import units from utility gets reduced. During mains fail condition or if the utility supply goes beyond the predefined safe limits, immidiately lift load will be transferred to iERD without any break (<2mS). On battery mode it will give @15 min back up. During battery mode, regenerative power will be utilized to recharge the batteries. On healthy grid supply resumption, lift load gets automatically retransferred to the grid without any break.

ECO mode Benefits

  • In normal UPS, load is always running on inverter, hence it consumes @10% more power as compared to ECO mode, due to double conversion losses.
  • In ECO mode regenerative power from LIFT gets fully utilized. Normally it gets wasted in the form of heat energy in other normal UPS.
  • In ECO mode life of all power electronics and wound components will be increased as inverter will come into operation only during grid failure.
  • Current harmonics reflected to the Grid are very less in iERD with ECO mode as compared to any normal UPS.
  • In ECO mode, the UPS charger is normally used mostly for charging the batteries so the ripple content is low as compared to double conversion mode, as a result the battery life and performance get improved.
  • The audible noise is also low (< 4-5 decibels) also the ambient temperature and that within the unit is low.

Renutron iERD Operation

RENUTRON iERD is specially recommended for high-speed LIFTS being used in high rise buildings. (High speed LIFTS using both regenerative and non-regerative drives)

Normal Operation

On mains mode, iERD will provide clean, safe and regulated power to the LIFT. Output power supply will be free from all types of power quality problems (like fluctuation, high / low voltage, spikes, frequency variation etc.) So it will ensure long life and jerk free operation of LIFT. Display provided in the LIFT car will show iERD status as running on mains mode.

Mains Fail Condition

When mains supply fails, or single phasing / phase reversal condition occurs, iERD shifts to battery backup mode. LIFT passenger will not experience any kind of jerks or power fail condition. LIFT will continue its normal operation as per the battery charge. Advanced Wireless Audio-Visual Display in lift car will show iERD status as running on battery mode, and also gives voice annunciation (LIFT IS RUNNING ON BATTERY MODE) to the passengers. Display will also annunciate if there is bnormal mains supply i.e., single phasing / phase reversal.

Battery Low Condition

In case of prolonged power cuts (or DG sets not taking over), batteries may get slowly exhausted. When battery voltage reaches to battery low pre-alarm level, iERD will indicate battery low pre-alarm message and LIFT car Display will give voice annunciation as well as text message - (BATTERY LOW, LIFT MAY STOP AT ANY TIME).

Emergency Rescue Operation

If iERD is further used after battery low pre-alarm and if batteries reaches to Battery Low Condition, iERD function automatically gets activated and avoids LIFT passengers getting trapped inside the LIFT car. On Battery backup mode, if battery low condition is occurred, iERD will first check if LIFT is in running condition, iERD will allow the LIFT to complete its travel. After LIFT travel is completed, the LIFT car doors will get automatically opened and the passengers get rescued and iERD will stop its operation to prevent batteries getting deeply discharged, and waits for Mains supply to get resumed. In this way, iERD ensures safety & jerk free operations for the passengers travelling inside the lift car and avoid panic situations. After this rescue operation, Advanced Wireless Audio-Visual Display will give voice annunciation as well as text message that LIFT IS STOPPED DUE TO BATTERY LOW. This prevents the false service calls to lift supplier or lift maintenance agency

20 Reasons Why You Should Choose Renutron iERD

  • 1. We are No.1 ERD / Lift back up manufacturers in India.
  • 2. We are a manufacturing company having 26+ years of experience.
  • 3. We have a vast domain knowledge in different types 250+ elevators/ escalators/hydraulic car parking systems.
  • 4. Our installation base for lift ERDs is over 4800+ across India.
  • 5. We are the very first one and experts in successfully supplying & installing ERDs for OTIS lifts with Regenerative Drives in Bangalore in 2017.
  • 6. Think Regenerative!! Think Renutron!!
  • 7. We invented the first wireless and voice enabled Lift car remote annunciation way back in 2005.
  • 8. We are the one having maximum number of successful lift car display installations for high-speed lifts in high rise towers.
  • 9. Our ERD System has a field proven design life of 18+ years and uptime above 98%.
  • 10. Regenerative Power Priority & Advanced ECO Mode solutions.
  • 11. Ideally suitable for Indian Power conditions
  • 12. Appreciated by Haryana State Govt inspection authorities
  • 13. Over 60 plus installations in NCR for high-speed lifts and high-rise buildings
  • 14. Over 50+ projects using Renutron iERD for lifts got approved for Occupation Certificates from Haryana State Govt
  • 15. Issued Safety Certificates to the projects with ERD
  • 16. Manufacturer having expertise in High Speed, High Rise & Regenerative Lifts.
  • 17. Only manufacturer in India with field proven ERD for Regenerative Lifts.
  • 18. ERD Model Range: 06 KVA to 250 KVA
  • 19. Highest Capacity ERD installed in Gurgaon: 60 KVA
  • 20. As of now, up to 34 floors, ERD is installed & tested okay

Wireless Audio-Visual 7” Capacitive Touch screen LCD with in-built speakers

  • 1024 x 600 screen resolution and IPS display panel.
  • Dimensions (L x W x H) mm: 191 x 17 x 115
  • Toughened glass capacitive touch panel, 6H hardness.
  • HDMI interface for displaying, USB interface for touch control.
  • Supports 5-level backlight adjustment.
ERD for High Rise Buildings | ERD for High-Speed Lifts
ERD for High Rise Buildings | ERD for High-Speed Lifts

Renutron iERD is more reliable and useful than ARD (which is a basically rescue device to the nearest floor, for passengers trapped in the lift car. Especially NOT USEFUL in high rise towers and with old age people.)

Renutron ERD’s Unique Features

Renutron ERD’s Unique Features
Renutron ERD’s Unique Features

The conventional eARD (Emergency Auto Rescue Device) with voice messaging facility was invented by RENUTRON R &D Team in 2008. It is useful in providing audio-visual status of Lift UPS to the passengers travelling through the lift car. Many a times the vital information (especially the unhealthy situation) remains unattended or not acted upon, which may result into lift stoppages and passengers getting stuck inside the lift car.

In order to overcome the short comings in eARD, RENUTRON has introduced yet another user friendly feature for Lift backup System users, namely built in GSM Modem. With the help of which Live updates about Lift UPS status to exact concerned person are now made possible. This is an Advanced and effective way of communication amongst Customer (builder), End user (society's concern person) & RENUTRON customer care team.

For this purpose, you need not have separate Wifi Connection. The normal SIM Card is fitted in GSM Modem which will send the SMS alerts to concern persons. We can add & save up to 5 Contact Numbers for this purpose.

Call Us : 9607196989